Maximator G-D Series High Pressure Liquid Pump
- Double acting
- Single air drive head
- Pressures to 4,500 bar (65,250 psi)
- They are suitable for use in zone 1, category 2G/2D IIC TX explosion-proof areas (Temperature class depending on medium temperature).
Examples of application for the G…-2 Series hydraulic pumps include:
- Hydrostatic tests: Valves, tanks, pressure vessels, pressure switches, hoses, pipes & tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas cylinders and components from the Aerospace technology.
- Burst and Cycle fatigue testing for parts mentioned above
- Calibration: Pressure gauges and transducers
- Water jet cutting and cleaning
- Leak testing
- Emergency shutdown systems for Oil & Gas Wells
- Pressurisation of accumulators for testing numerous components
- Operation and Control of well service and well head equipment
G…D Pumps
- Double acting
- Single air drive head
- Pressures to 4,500 bar (65,250 psi)
G…D pumps are double acting, single air drive head. They are characterised by the same features as the G pumps single acting, single air drive head types, but they have less pulsations and deliver approx. 50 % more flow.
G…D pumps are available with polyurethane seals, UHMWPE seals with Viton O-ring for water use are available as option. Models G10D – G35D come standard with bottom inlet, side inlet is available as option. Models G60D(S) – G150D(S) are only available with side inlet. For air drive pressures of 14.5 psi (1 bar) minimum to 145 psi (10 bar) maximum.
Options for G Series
- Seal material for oil use (standard pump): Order code: G35 – (L)
- Seal material for water use: (not available for G500 and G500-2) Order code: G35 – (L)VE / G37D – VE
- Special seal material to handle special fluids: Order code: See fluid compatibility guide
- Side inlet (G500, G500-2 and G60 – G150 come standard with side inlet) Order code: G35(L) – S / G35(D)VE – S
- Special inlet and outlet ports (i. e. NPT): Order code: G35 – NPT
- Air control unit for G series with filter pressure regulator, control pressure gauge and shut-off valve: Order code: G35(L) with C2
- To protect the pump against excessive outlet pressures, an air safety valve can be fitted to the air control unit: Order code: G35(L) with C2/SVair (The outlet pressure has to be indicated.)
- Other options available on request.
Type | Pressure Ratio |
Displacement volume2) cm³ |
Displacement volume2) in³ |
P max.*’ bar |
P max.* psi |
Flow cfm |
Flow l/min |
---|---|---|---|---|---|---|---|
G10D | 1:10 | 180.00 | 10.98 | 100 | 1450 | 1.01 | 28.85 |
G15D | 1:15 | 124.00 | 7.57 | 150 | 2175 | 0.69 | 19.84 |
G25D | 1:27 | 70.60 | 4.31 | 270 | 3915 | 0.41 | 11.84 |
G35D | 1:63 | 29.00 | 1.77 | 400 | 5800 | 027 | 7.74 |
G60D | 1:63 | 31.40 | 1.92 | 630 | 9135 | 0.18 | 5.04 |
G100D | 1:113 | 17.60 | 1.07 | 1050 | 15225 | 0.10 | 2.78 |
G150D | 1:151 | 7.60 | 0.46 | 1450 | 21025 | 0.07 | 2.10 |
P max. = Discharge