Additel ADT761A Portable Automated Pressure Calibrator
ADT761A – Automated and self-contained pressure generation and control Pressures from -30 in H2O (-75 mbar) to 1000 psi (70 bar) with 0.02% FS accuracy. HART and profibus communication. 6 models available.
Additel ADT761A Pressure Calibration Equipment
The Additel series of ADT761A automated pressure calibration equipment. For Automatic pressure gauge calibration, pressure transmitter calibration & Pressure Switch calibration.
- Automated and self-contained pressure generation and control to 1,000 psig ( 70 bar.g)
- 0.02%FS accuracy
- Two removable internal pressure modules for multi-range selection
- Control stability to 0.005%FS
- Portable, designed for use in the field and in the lab
- Ability to measure two external pressure modules
- Wi-Fi, Bluetooth, USB and Ethernet communication
- HART and profibus communication
- Data logging and task management
- Patented electric pump technology and improved speed
Videos
Additel ADT761 DP Transmitter Calibration
ADT761A-500
The Additel ADT761A-500 will generate and control from vacuum pressures up to 500 psig (35 bar.g). Both gauge and absolute pressures can be realized due to a built-in barometer. Each unit comes with a CP500 module (-12.5 to 500 psig) for the high range and the low range can be preconfigured based on the variety of modules available down to 10 psig (0.7 bar.g).
ADT761A-1K
The Additel ADT761A-1K will generate and control from vacuum pressures up to 1,000 psig (70 bar.g). This unit can typically achieve 1,000 psi in less than 45 seconds. Like the ADT761A-500, both gauge and absolute pressures can be realized due to a built-in barometer. Each unit comes with a CP1K module (-12.5 to 1,000 psig) for the high range and the low range can be preconfigured based on the variety of modules available down to 30 psig (2 bar.g).
ADT761A-LLP
The Additel ADT761A-LLP is designed for low pressure calibration and comes with a ±30 inH2O (±75 mbar) high range module and a low range module of your choice ranging from ±20 inH2O to as low as ±0.25 inH2O (±50 to ±0.62 mbar). This unit has an accuracy of 0.05%FS with control stability better than 0.005%FS. All measurements can be made in differential or gauge pressures.
ADT761A-D
The Additel ADT761A-D also provides differential and gauge measurement which covers the range of -13.5 to 35 psi (-0.95 to 2.5 bar). This unit comes with a CP35 module (-13.5 to 35 psi) and one low range module of your choice ranging as low as ±10 inH2O (25 mbar). Each ADT761A-D can be preconfigured with the modules that fit your need to give you the best precision at the pressures you perform calibrations.
ADT761A-BP
The Additel ADT761A-BP is designed for calibration of barometer sensors. With a range of 100 to 1200 hPa and an accuracy of 0.01%FS, this unit is ideal for calibration on the bench or in the field.
ADT761A-APXR Precision Accuracy Options
The Additel ADT761A series includes a precision accuracy option which provides an accuracy of 0.01%FS. This calibrator option includes a single non-removable sensor and can measure absolute and gauge pressures. Model configurations are available from 15 to 1,000 psig (1 to 7 bar.g).
- High Pressure Automatic Calibration
- Pressure Gauge, Transmitter or Switch Calibration
- Task Selector
ADT761A Selection Guide
ADT761 Battery Material Safety Data Sheet
Pressure Specifications | ||||||
---|---|---|---|---|---|---|
Specification | 761A-LLP | 761A-D | 761A-500 | 761A-1K | 761A-APXR | 761A-BP |
Max Pressure Range | 30 inH2O (75 mbar) | 35 psi (2.5 bar) | 500 psig (35 bar.g) | 1,000 pisg (70 bar.g) | Dependent on APXR | 1,200 hPasensor |
Min Pressure Range | -30 inH2O (-75 mbar) | -13.5 psi (-0.95 bar) | -13 psi (-0.9 bar) | -13 psi (-0.9 bar) | Dependent on APXR | 100 hPasensor |
Accuracy(1) | 0.05%FS | 0.02%FS | 0.02%FS | 0.02%FS | 0.01%FS | 0.01%FS |
Stability | 0.005%FS or 0.05 Pa | 0.005%FS | 0.005%FS | 0.005%FS | 0.003%FS | 0.02 hPa |
Pressure Type | Differential, Gauge | Differential, Gauge | Gauge, Absolute | Gauge, Absolute | Gauge, Absolute | Absolute |
Over Range Indication | 1.2 | |||||
Resolution | 6 digits | |||||
Measurement Units | Pa, hPa, kPa, mPa, bar, mbar, psi, mmHg@0°C, cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, inH2O@20°C, kg/m2, mtorr, torr, lb/ft2, tsi, custom | |||||
Barometric Accuracy | N/A | N/A | 55 Pa | 55 Pa | 55 Pa | N/A |
[1] One year accuracy (including 1 year stability). FS specification applies to the span of the module range. | ||||||
[2] Specification based on gauge measurement. An additional 60 pa uncertainty will need to be included when measuring in absolute mode. Applicable only for use with the ADT761A-500 and ADT761A-1K | ||||||
* Additel 761A calibrators support 160A intelligent digital pressure modules that are available for gauge, vacuum and absolute pressure from -15 psi to 60,000 psi (-1 bar to 4200 bar).For detailed specs, see the 160A pressure module data sheet. |
Electrical Specifications | ||||
---|---|---|---|---|
Specification | Range | Resolution | Accuracy | Note |
mA Measure | Range selectable | 0.0001 mA | 0.008%RD+0.002%FS | Impedance <10Ω |
±25 or ±50 mA | ||||
V Measure | ±300 mV | 0.1 μV | 0.008%RD+0.002%FS | Impedance >1GΩ |
Range selectable | 0.0001 V | 0.008%RD+0.002%FS | Impedance >1MΩ | |
±5, ±12 or ±30 V | ||||
Loop Power Source | 24V | N/A | ±1 V | 50 mA (Max Loading) |
mA Source | 0.2 to 2.5 mA or 2.5 to 25 mA | 0.1 μA | 0-2.5 mA: 0.008%RD+0.1 μA | 20 mA @ 1KΩ |
0-25 mA: 0.008%RD+0.5 μA | ||||
Power Source | 16 to 30 V | 1 V | ±0.1% RD | 70 mA (Max Loading) |
V Source | 0 to 12 V | 0.0001 V | 0.008%RD+0.002%FS | |
Pressure Switch | Mechanical Switch, Live Mechanical Switch, NPN Switch, PNP Switch | N/A | N/A | Response time<10 ms. If the switch is live, voltage range will be (3-30) V |
Temperature Compensation | 5°C to 35°C | |||
Temperature Coefficient | Outside of 5°C to 35°C: <±0.0005%RD+0.0001%FS/°C | |||
Misuse Protection | Up to 30 V on any two sockets |
Internal Module Specification and Compatibility | |||||||||
---|---|---|---|---|---|---|---|---|---|
Model | inH2O | mbar | Media | Accuracy (%FS)(1) | Burst Pressure | 761A-LLP | 761A-D | 761A-500 | 761A-1K |
ADT155-DP025 | ±0.25 | ±0.62 | G | 0.2 (2) | 100x | • | |||
ADT155-DP050 | ±0.5 | ±1.25 | G | 0.1(3) | 100x | • | |||
ADT155-DP1 | ±1 | ±2.5 | G | 0.05(4) | 100x | • | |||
ADT155-DP2 | ±2 | ±5 | G | 0.05(4) | 100x | • | |||
ADT155-DP5 | ±5 | ±10 | G | 0.05(4) | 50x | • | |||
ADT155-DP10 | ±10 | ±25 | G | 0.05(4) | 20x | • | • | ||
ADT155-DP20 | ±20 | ±50 | G | 0.05 | 20x | • | • | ||
ADT155-DP30 | ±30 | ±75 | G | 0.05 | 20x | • | • | ||
ADT155-DP50 | ±50 | ±160 | G | 0.05 | 3x | • | |||
ADT155-DP150 | ±150 | ±350 | G | 0.02 | 3x | • | |||
ADT155-DP300 | ±300 | ±700 | G | 0.02 | 3x | • | |||
ADT155-DP400 | -380 to 400 | -950 to 1K | G | 0.02 | 3x | • | |||
ADT155-DP800 | -380 to 800 | -950 to 2K | G | 0.02 | 3x | • | |||
ADT155-DP1K | -380 to 1K | -950 to 2.5K | G | 0.02 | 3x | • | |||
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules. | |||||||||
[2] Accuracy is a 6 months spec, 1-year long-term drift is 0.2%FS. | |||||||||
[3] Accuracy is a 6 months spec, 1-year long-term drift is 0.1%FS. | |||||||||
[4] Accuracy is a 6 months spec, 1-year long-term drift is 0.05%FS. | |||||||||
[5] Specification based on gauge measurement. An additional 50 pa uncertainty will need to be included when measuring in absolute mode.Applicable only for use with the ADT761A-500 and ADT761A-1K. |
Internal Module Specification and Compatibility (Gauge Pressure) | |||||||||
---|---|---|---|---|---|---|---|---|---|
Model | psig | bar.g | Media | Accuracy (%FS)(1) | Burst Pressure | 761A-LLP | 761A-D | 761A-500 | 761A-1K |
ADT155-CP10 | ±10 | ±0.7 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP15 | -12.5 to 15 | -0.95 to 1 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP30 | -12.5 to 30 | -0.95 to 2 | G | 0.02(5) | 3x | • | • | • | |
ADT155-CP35 | -12.5 to 35 | -0.95 to 2.5 | G | 0.02(5) | 3x | • | • | • | |
ADT155-CP50 | -12.5 to 50 | -0.90 to 3.5 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP100 | -12.5 to 100 | -0.90 to 7 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP150 | -12.5 to 150 | -0.90 to 10 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP200 | -12.5 to 200 | -0.90 to 14 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP300 | -12.5 to 300 | -0.90 to 20 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP500 | -12.5 to 500 | -0.90 to 35 | G | 0.02(5) | 3x | • | • | ||
ADT155-CP600 | -12.5 to 600 | -0.90 to 40 | G | 0.02(5) | 3x | • | |||
ADT155-CP1K | -12.5 to 1K | -0.90 to 70 | G | 0.02(5) | 3x | • | |||
[1] FS specification applies to the span of the module range. Accuracy includes one-year stability, except for DP025 to DP10 modules. | |||||||||
[5] Specification based on gauge measurement. An additional 50 pa uncertainty will need to be included when measuring in absolute mode.Applicable only for use with the ADT761A-500 and ADT761A-1K. |
General Specifications | |
---|---|
Specification | Description |
User Interface | Color touch screen and/or keypad operation |
Four total: one electrical, high or low internal | |
Channels | pressure module, two external pressure modules |
Enclosure IP Rating | IP31 |
Battery | Rechargeable Li-Ion battery, typically 16 hours of operation, recharges in less than 5 hours. |
Power | Rechargeable Li-Ion battery, external power 110/220 V power adapter 27 V |
Display | 7” TFT touch screen 800 x 480 color |
Communications | USB, LAN, Bluetooth, Wi-Fi |
Weight | <17.52 lb (7.95 KG) |
Size | 11.77 x 7.60 x 7.56 in (299 x 193 x 192 mm) |
Certification | ISO17025 accredited certificate of calibration with NIST-traceable data |
Data Storage | 6 GB |
Data Logging | Up to 1,000,000 readings (data and time stamped) |
Task documentation | Up to 1000 tasks can be stored with data |
Automation Functions | Switch test, auto step, leak test |
User Interface Localization | English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian |
Pump life | >100,000 cycles |
Environmental Specifications | Operating temperature: 32 °F to 122 °F( 0°C to 50°C) |
Compensated temperature: 32 °F to 122 °F( 0°C to 50°C) | |
Storage temperature: -20°C to 60°C ( -4 °F to 120 °F) | |
Humidity: <90%, non-condensing | |
Vibration and Shock | Vibration: 4g (20 to 2,000 Hz) |
Shock: 8g, 1 meter drop test | |
Compliance | CE |
Software Compatibility | ACal, Additel Land and Additel Link for access via mobile application |
Warranty | 1 year |
Pressure Range | ||||||
---|---|---|---|---|---|---|
Type | Model | Pressure Range | High-Range Pressure Module | Low-Range Pressure Module | ||
Range | Accuracy | Range | Accuracy | |||
Low/Differential Pressure | ADT761A-LLP | -75 to 75 mbar (-30 to 30 inH2O) | DP30: -75 to 75 mbar (-30 to 30 inH2O) | 0.05%FS | User selectable from DP20 to DP025 | See Internal Module Table |
ADT761A-D | -0.95 to 2.5 bar (-13.5 to 35 psi) | CP35: -0.95 to 2.5 bar (-13.5 to 35 psi) | 0.02%FS | User selectable from DP10 to CP30 | See Internal Module Table | |
Standard Accuracy Gauge/Absolute Pressure | ADT761A-500 | -0.9 to 35 bar (-13 to 500 psi) | CP500: -0.9 to 35 bar (-13 to 500 psi) | 0.02%FS | User selectable from CP10 to CP300 | See Internal Module Table |
ADT761A-1K | -0.9 to 70 bar (-13 to 1000 psi) | CP1K: -0.9 to 70 bar (-13 to 10000 psi) | 0.02%FS | User selectable from CP30 to CP600 | See Internal Module Table | |
Precision Accuracy Gauge/Absolute Pressure | ADT761A-30R | -0.95 to 1 bar (-13.5 to 15 psi) | AP30R: -0.95 to 1 bar (-13.5 to 15 psi) | 0.01%FS | Single sensor only | |
ADT761A-50R | -0.95 to 2.5 bar (-13.5 to 35 psi) | AP50R: -0.95 to 2.5 bar (-13.5 to 35 psi) | 0.01%FS | Single sensor only | ||
ADT761A-100R | -0.95 to 7 bar (-13.5 to 100 psi) | AP100R: -0.95 to 7 bar (-13.5 to 100 psi) | 0.01%FS | Single sensor only | ||
ADT761A-300R | -0.9 to 21 bar (-13 to 300 psi) | AP300R: -0.9 to 21 bar (-13 to 300 psi) | 0.01%FS | Single sensor only | ||
ADT761A-500R | -0.9 to 35 bar (-13 to 500 psi) | AP500R: -0.9 to 35 bar (-13 to 500 psi) | 0.01%FS | Single sensor only | ||
ADT761A-1KR | -0.9 to 70 bar (-13 to 1000 psi) | AP1KR: -0.9 to 70 bar (-13 to 1000 psi) | 0.01%FS | Single sensor only |